✨ Electricity Performance Measures
Buller Electricity Limited
Line Business Performance Measures
| 2007 | 2006 | 2005 | 2004 |
|---|
SAIDI
-
SAIDI for the total number of interruptions | 355 | 196 | 134 | 256 |
-
SAIDI targets for 2007/2008
- Class B - Planned by Line Owners | 136 |
- Class C - Unplanned by Line Owners | 87 |
- Average SAIDI targets for 2008/2012 years
- Class B - Planned by Line Owners | 110 | 137 |
- Class C - Unplanned by Line Owners | 79 | 78 |
- SAIDI for the total number of interruptions within each interruption class
| Class Description | 2007 | 2006 | 2005 | 2004 |
|---|---|---|---|---|
| Class A - Planned by Transpower | 0 | 0 | 0 | 0 |
| Class B - Planned by Buller Electricity | 109 | 108 | 64 | 165 |
| Class C - Unplanned by Buller Electricity | 53 | 84 | 65 | 84 |
| Class D - Unplanned by Transpower | 193 | 4 | 0 | 0 |
| Class E - Unplanned by Line Owner generation | 0 | 0 | 0 | 0 |
| Class F - Unplanned by other generator | 0 | 0 | 0 | 0 |
| Class G - Unplanned – by another Line Owner | 0 | 0 | 0 | 0 |
| Class H - Planned – by another Line Owner | 0 | 0 | 0 | 0 |
| Class I - Any Other Loss of Supply | 0 | 0 | 5 | 8 |
| Total | 355 | 196 | 134 | 257 |
SAIFI
-
The SAIFI for the total number of Interruptions | 3.24 | 1.88 | 1.34 | 2.41 |
-
SAIFI Targets for 2007/2008
- Class B - Planned by Line Owners | 0.74 |
- Class C - Unplanned by Line Owners | 1.01 |
- Average SAIFI targets for 2008/2012 years
- Class B - Planned by Line Owners | 0.54 | 0.79 |
- Class C - Unplanned by Line Owners | 1.12 | 0.94 |
- The SAIFI for the total number of interruptions within each interruption class
| Class Description | 2007 | 2006 | 2005 | 2004 |
|---|---|---|---|---|
| Class A - Planned by Transpower | 0.00 | 0 | 0.00 | 0.00 |
| Class B - Planned by Buller Electricity | 0.42 | 0.62 | 0.44 | 1.01 |
| Class C - Unplanned by Buller Electricity | 0.87 | 1.18 | 0.78 | 1.22 |
| Class D - Unplanned by Transpower | 1.95 | 0.08 | 0.00 | 0.00 |
| Class E - Unplanned by Line Owner generation | 0 | 0 | 0.00 | 0.00 |
| Class F - Unplanned by other generator | 0 | 0 | 0.00 | 0.00 |
| Class G - Unplanned – by another Line Owner | 0 | 0 | 0.00 | 0.00 |
| Class H - Planned – by another Line Owner | 0 | 0 | 0.00 | 0.00 |
| Class I - Any Other Loss of Supply | 0 | 0 | 0.12 | 0.17 |
| Total | 3.24 | 1.88 | 1.34 | 2.41 |
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2008, No 21
Gazette.govt.nz —
NZ Gazette 2008, No 21
✨ LLM interpretation of page content
🏭
Buller Electricity Limited Line Business Performance Measures
(continued from previous page)
🏭 Trade, Customs & IndustryElectricity, Performance Measures, Interruptions, Faults, Reliability, Buller Electricity Limited