✨ Regulation 22: Reliability Performance Measures




12 NOVEMBER NEW ZEALAND GAZETTE 4029

Regulation 22: Reliability Performance Measures

(1) Total Number of Interruptions

                  1999    1998    1997    1996
Class A             0       0       0       0
Class B           376     485     481     361
Class C           140     131     190     164
Class D             0       0       0       0
Class E             0       0       0       0
Class F             0       0       0       0
Class G             0       0       0       0
Total             516     619     672     525

(2) Interruption targets for the following financial year
(a) Class B 338
(b) Class C 133

(3) Average interruption targets for the following financial year and subsequent 4 financial years
(a) Class B 277
(b) Class C 120

(4) The proportion of the total number of Class C interruptions not restored within:
(a) 3 hrs 19.23%
(b) 24 hrs 0.00%

(5)
(a) The number of faults per 100 circuit kilometres of prescribed voltage electric line
1999 1998 1997 1996
5.99 5.60 7.70 7.02

(b) The total number of faults per 100 circuit kilometres of prescribed voltage electric line
    targeted for the following financial year
    5.69

(c) The average total number of faults per 100 circuit kilometres of prescribed voltage electric line
    targeted for that financial year and the subsequent 4 financial years
    5.13

(d) A breakdown of the total number of faults per 100 circuit kilometres of prescribed voltage electric line
                    1999    1998    1997    1996
    - 50kV          5.04    5.81    7.39    6.23
    - 11kV          6.11    5.58    8.22    7.12
    A breakdown of the total number of faults per 100 circuit kilometres of prescribed voltage electric line targeted for the following financial year
    - 50kV          4.79
    - 11kV          5.80
    A breakdown of the average total number of faults per 100 circuit kilometres of prescribed voltage electric line targeted for that financial year and the subsequent 4 financial years
    - 50kV          4.32
    - 11kV          5.32


Next Page →

PDF embedding disabled (Crown copyright)

View this page online at: