Gasfitting Regulations




12 SEPTEMBER 2012 NEW ZEALAND GAZETTE, No. 112 3187

(e) Access to, and application of, relevant documentation relating to gasfitting to meet compliance requirements, and an understanding of the regulatory environment. Descriptors include, but are not limited to—

(i) Acts and Regulations;

(ii) standards;

(iii) codes;

(iv) manufacturers’ instructions.

(f) Management of the effect on the integrity of structures relating to the design and installation of gasfitting systems, including weather tightness considerations as they relate to penetrations to the building envelope and coordination with other services. Descriptors include, but are not limited to—

(i) preservation of structural integrity;

(ii) prevention of damage to property including weather tightness;

(iii) positioning and protection of services along with the coordination with other building services.

(g) Responsibilities relating to managing health and safety. Descriptors include, but are not limited to health and safety systems, and preparation of safety plans.

(h) Responsibilities relating to the oversight and/or supervision of persons who do, or assist in doing, gasfitting work."

Paragraphs 3(1), (2), (3) and (4) amended

(2) Replace paragraphs 3(1), (2), (3) and (4) in the Schedule with:

"(1) To be eligible to be issued with a certifying gasfitter practising licence, an applicant must, during the licensing period concluding immediately before the licensing period for which the licence application is being made, have obtained a minimum number of continuing professional development (“CPD”) points (“CPD points”).

(1A) Of the CPD points required by a certifying gasfitter for each licensing period, an applicant must have obtained at least 75% of the CPD points by successfully completing board-accredited CPD courses, and a maximum of 25% of the CPD points by completing self-directed learning, as set out in the following table:

Practising licences CPD points for each licensing period
Certifying gasfitter practising licence only 12 CPD points, of which—
• at least 9 points must be from board-accredited CPD courses; and
• up to 3 points may be acquired through self-directed learning
Certifying gasfitter practising licence and one 20 CPD points, of which—
of the following— • at least 15 points must be from board-accredited CPD courses; and
• certifying drainlayer practising licence • up to 5 points may be acquired through self-directed learning
• licensed drainlayer practising licence
• certifying plumber practising licence
• licensed plumber practising licence


Next Page →



Online Sources for this page:

Gazette.govt.nz PDF NZ Gazette 2012, No 112





✨ LLM interpretation of page content

🏭 Plumbers, Gasfitters, and Drainlayers Board (Gasfitting Registration and Licensing) Amendment Notice 2012 (continued from previous page)

🏭 Trade, Customs & Industry
12 September 2012
Plumbers, Gasfitters, Drainlayers, Registration, Licensing, Amendment, Competencies, CPD, Examination, Gasfitting