β¨ Electricity Lines Business Performance Measures
VECTOR LIMITED
ELECTRICITY LINES BUSINESS
ENERGY DELIVERY EFFICIENCY PERFORMANCE MEASURES AND STATISTICS
FOR THE YEAR ENDED 31 MARCH 2007
SCHEDULE 1 β PART 4
- Energy delivery efficiency performance measures
| 2007 | 2006 | 2005 | 2004 | |
|---|---|---|---|---|
| (a) Load factor | 57.17% | 59.13% | 58.81% | 59.81% |
| (b) Loss ratio | 4.73% | 4.91% | 4.65% | 4.72% |
| (c) Capacity utilisation | 43.77% | 41.39% | 42.29% | 40.42% |
- Statistics
(a) System length excluding street lighting (in kilometres)
| 400V | 6.6kV | 11kV | 22kV | 33kV | 66kV | 110kV | Total | |
|---|---|---|---|---|---|---|---|---|
| 2007 | 11,844.37 | 68.18 | 8,679.92 | 145.88 | 914.99 | 0.00 | 90.62 | 21,743.95 |
| 2006 | 11,747.75 | 67.43 | 8,638.40 | 144.90 | 917.31 | 0.00 | 90.63 | 21,606.42 |
| 2005 | 11,638.52 | 67.17 | 8,571.24 | 125.68 | 910.38 | 0.00 | 91.30 | 21,404.29 |
| 2004 | 11,481.46 | 66.54 | 8,487.72 | 125.24 | 911.60 | 0.00 | 90.48 | 21,163.04 |
(b) Total circuit length excluding street lighting (in kilometres) of overhead electric lines
| 400V | 6.6kV | 11kV | 22kV | 33kV | 66kV | 110kV | Total | |
|---|---|---|---|---|---|---|---|---|
| 2007 | 5,393.00 | 24.59 | 4,481.20 | 6.97 | 435.98 | 0.00 | 25.73 | 10,367.47 |
| 2006 | 5,371.28 | 25.02 | 4,486.26 | 7.44 | 436.35 | 0.00 | 25.74 | 10,352.09 |
| 2005 | 5,396.52 | 26.43 | 4,486.96 | 2.91 | 437.89 | 0.00 | 26.74 | 10,376.47 |
| 2004 | 5,417.57 | 26.43 | 4,495.66 | 2.91 | 446.11 | 0.00 | 25.74 | 10,414.42 |
(c) Total circuit length excluding street lighting (in kilometres) of underground electric lines
| 400V | 6.6kV | 11kV | 22kV | 33kV | 66kV | 110kV | Total | |
|---|---|---|---|---|---|---|---|---|
| 2007 | 6,451.37 | 43.59 | 4,198.72 | 138.91 | 479.01 | 0.00 | 64.89 | 11,376.48 |
| 2006 | 6,376.47 | 41.51 | 4,152.14 | 137.46 | 480.96 | 0.00 | 64.89 | 11,253.43 |
| 2005 | 6,242.00 | 40.74 | 4,084.26 | 122.78 | 472.48 | 0.00 | 65.56 | 11,027.82 |
| 2004 | 6,063.89 | 40.11 | 3,992.06 | 122.33 | 465.49 | 0.00 | 64.74 | 10,748.62 |
2(a) 2(b) 2(c)
- 400V includes 52km of DC power systems.
- Per energised voltage.
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2008, No 39
Gazette.govt.nz —
NZ Gazette 2008, No 39
β¨ LLM interpretation of page content
π
Energy Delivery Efficiency Performance Measures and Statistics for Vector Limited
(continued from previous page)
π Trade, Customs & IndustryEnergy delivery, Load factor, Loss ratio, Capacity utilisation, System length, Circuit length, Electric lines, Vector Limited