β¨ Westpower Limited Statistics
WESTPOWER LIMITED - LINES BUSINESS
(c) System Length - Underground
| 2006 | 2005 | 2004 | 2003 | |
|---|---|---|---|---|
| Circuit Kilometres 66kV | 0 | 0 | 0 | 0 |
| Circuit Kilometres 33kV | 2 | 2 | 2 | 0 |
| Circuit Kilometres 11kV | 40 | 37 | 33 | 34 |
| Circuit Kilometres 230/400V | 87 | 87 | 87 | 61 |
Total Underground | 129 | 126 | 122 | 95 |
(d) Transformer Capacity (In Kilovolt Amperes)
| 2006 | 2005 | 2004 | 2003 | |
|---|---|---|---|---|
| District (zone) Substations | 151,000 | 107,000 | 107,000 | 96,000 |
| Distribution Substations | 127,000 | 119,309 | 116,726 | 109,003 |
| Total Substations | 278,000 | 226,309 | 223,726 | 205,003 |
(e) Maximum Demand | 39,292 | 37,172 | 36,024 | 38,232 |
(f) Total electricity supplied from the system before losses (in Kilowatt Hours)
| 223,809,000 | 209,115,825 | 207,165,465 | 211,261,285 |
(g) Electricity conveyed for each retailer after losses
| Retailer 1 | 14,578,000 | 3,153,752 | - | - |
| Retailer 2 | - | - | - | - |
| Retailer 3 | 2,750,000 | 3,887,007 | 9,791,672 | 8,631,685 |
| Retailer 4 | 16,651,000 | 15,742,067 | 14,192,942 | 25,028,359 |
| Retailer 5 | 23,734,000 | 12,938,446 | 9,920,251 | 9,053,917 |
| Retailer 6 | 153,273,000 | 161,046,503 | 158,826,600| 158,943,487|
| Retailer 7 | - | - | - | - |
Total Conveyed | 210,984,000 | 196,767,775 | 192,731,465| 201,657,448|
(h) Total Consumers *
| 12,010 | 12,031 | 11,931 | 12,077 |
- Number of consumers based on ICP connections
Disclosure of reliability performance measures under requirement 21 of the Electricity (Information Disclosure) Requirements 2004 Schedule 1 Part 5
1 Total number of interruptions
| Class | Description | 2006 | 2005 | 2004 | 2003 |
|---|---|---|---|---|---|
| A | Planned - by Transpower | 0 | 2 | 4 | 0 |
| B | Planned - by Line Owners | 63 | 140 | 50 | 63 |
| C | Unplanned - by Line Owners | 122 | 136 | 171 | 57 |
| D | Unplanned - by Transpower | 2 | 6 | 1 | 0 |
| E | Unplanned - by ECNZ | 0 | 0 | 0 | 0 |
| F | Unplanned - by other generation | 0 | 0 | 0 | 0 |
| G | Unplanned - by other line owner | 0 | 0 | 0 | 0 |
| H | Planned - by other line owner | 0 | 0 | 0 | 0 |
| I | Any other loss of supply | 0 | 0 | 0 | 0 |
Total | 187 | 284 | 226 | 120 |
2 Interruption targets for 2006/2007
| Class B - Planned - by Line Owners | 60 |
| Class C - Unplanned - by Line Owners | 60 |
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2006, No 145
Gazette.govt.nz —
NZ Gazette 2006, No 145
β¨ LLM interpretation of page content
π°
Westpower Limited System Length Statistics
(continued from previous page)
π° Finance & RevenueSystem length, Circuit kilometres, Underground system length, Transformer capacity, Maximum demand, Electricity supply, Retailers, Consumers, Interruptions, Reliability performance