✨ Electricity Performance Measures
128 NEW ZEALAND GAZETTE, No. 5 14 JANUARY 2005
| 2004 | 2003 | 2002 | 2001 | |
|---|---|---|---|---|
| (d) Transformer capacity (kVA) | 758,211 | 740,166 | 725,937 | 708,484 |
| (c) Maximum demand (kW) | 246,190 | 271,850 | 262,700 | 252,775 |
| (f) Total electricity supplied before losses from the system (kWh) | 1,269,877,041 | 1,300,088,384 | 1,240,262,196 | 1,233,772,778 |
(g) Electricity conveyed after losses for each party (kWh)
| Party | 2004 | 2003 | 2002 | 2001 |
|---|---|---|---|---|
| Party 1 | 559,134,598 | 549,017,685 | 476,920,650 | 615,940,905 |
| Party 2 | 372,571,922 | 404,561,670 | 415,684,154 | 306,147,867 |
| Party 3 | 214,527,945 | 198,173,212 | 175,438,820 | 92,478,219 |
| Party 4 | 4,623,330 | 29,942,765 | 21,637,496 | 26,558,721 |
| Party 5 | 20,742,113 | 28,311,598 | 20,808,949 | 12,602,206 |
| Party 6 | 15,450,111 | 6,069,136 | 10,245,858 | 17,021,543 |
| Party 7 | 2,302,073 | 2,619,514 | 2,882,468 | 2,835,344 |
| Party 8 | 36,594 | - | - | - |
| Party 9 | - | 9,072 | 19,288 | - |
| Party 10 | - | - | 36,562,064 | 67,595,773 |
| Party 11 | - | - | 448,257 | 2,717,456 |
| Party 12 | - | - | 321,492 | 229,913 |
| Party 13 | - | - | - | 15,419,780 |
| Party 14 | - | - | - | 161,825 |
| (h) Total consumers | 73,972 | 72,794 | 71,431 | 70,208 |
Disclosure of reliability performance measures under requirement 21 of the Electricity Information Disclosure Requirements 2004
1 Total number of interruptions
| Interruption Class | 2004 | 2003 | 2002 | 2001 |
|---|---|---|---|---|
| Class A – planned by Transpower | 0 | 0 | 0 | 0 |
| Class B – planned by line owners | 293 | 341 | 228 | 209 |
| Class C – unplanned by line owners | 453 | 464 | 390 | 407 |
| Class D – unplanned by Transpower | 1 | 3 | 1 | 1 |
| Class E – unplanned by embedded generation | 0 | 0 | 0 | 0 |
| Class F – unplanned by generation on other networks | 0 | 0 | 0 | 0 |
| Class G – unplanned by other line owner | 0 | 0 | 0 | 0 |
| Class H – planned by another line owner | 0 | 0 | 0 | 0 |
| Class I – any other loss of supply | 0 | 0 | 0 | 0 |
2 No of interruption targets for next financial year
| Interruption Class | 2005 target |
|---|---|
| Class B – planned by line owners | 300 |
| Class C – unplanned by line owners | 450 |
3 Average no of interruption targets for next 5 years
| Interruption Class | Average Target |
|---|---|
| Class B – planned by line owners | 280 |
| Class C – unplanned by line owners | 420 |
4 Proportion of Class C interruptions not restored within
| Time | 2004 | 2003 | 2002 | 2001 |
|---|---|---|---|---|
| 3 hours | 16.6% | 13.7% | 11.0% | 10.8% |
| 24 hours | 0.9% | 0.2% | 0.0% | 0.0% |
5 (a) and (d) The total number of faults per 100 circuit kilometres of prescribed voltage electric line
| Voltage | 2004 | 2003 | 2002 | 2001 |
|---|---|---|---|---|
| 66 kV | 1.8 | 3.4 | 2.2 | 1.2 |
| 33 kV | - | 4.4 | - | - |
| 11 kV | 12.6 | 12.2 | 11.0 | 11.8 |
| 6.6 kV | 6.0 | 6.9 | 5.1 | 4.9 |
| Total | 9.5 | 9.6 | 8.0 | 8.2 |
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2005, No 5
Gazette.govt.nz —
NZ Gazette 2005, No 5
✨ LLM interpretation of page content
🏭
Disclosure of Financial and Efficiency Performance Measures for Electricity
(continued from previous page)
🏭 Trade, Customs & IndustryElectricity, Performance Measures, Financial, Efficiency, Energy Delivery, Transformer Capacity, Maximum Demand, Electricity Supply, Consumers
🏭 Disclosure of Reliability Performance Measures for Electricity
🏭 Trade, Customs & IndustryElectricity, Reliability, Interruptions, Performance Measures, Faults, Voltage