β¨ Electricity Reliability Performance Measures
18 JANUARY 2005
NEW ZEALAND GAZETTE, No. 13
303
6
Total Number Of Faults Per 100km Of Prescribed Voltage Underground Line
| Nominal Voltage | 2004 Powerco Number of Faults/100km | 2003 Powerco Number of Faults/100km | 2002 Powerco Number of Faults/100km | 2001 Powerco Number of Faults/100km |
|---|---|---|---|---|
| 110kV | - | - | - | - |
| 66kV | - | - | - | - |
| 33kV | 2.95 | 0.58 | - | - |
| 22kV | - | - | - | - |
| 11kV | 6.84 | 4.08 | 4.25 | 3.29 |
| 6.6kV | - | - | - | - |
| 3.3kV | - | 3.78 | 3.83 | 2.94 |
| Total | 5.54 | 3.05 | 3.07 | 2.55 |
7
Total Number Of Faults Per 100km Of Prescribed Voltage Overhead Line
| Nominal Voltage | 2004 Powerco Number of Faults/100km | 2003 Powerco Number of Faults/100km | 2002 Powerco Number of Faults/100km | 2001 Powerco Number of Faults/100km |
|---|---|---|---|---|
| 110kV | 3.33 | 9.32 | - | 3.59 |
| 66kV | - | - | 4.17 | - |
| 33kV | 10.72 | 6.80 | - | - |
| 22kV | 19.68 | 12.18 | 13.04 | 13.27 |
| 11kV | 15.14 | 12.32 | 9.17 | 11.66 |
| 6.6kV | 6.46 | 4.86 | - | 5.34 |
| 3.3kV | - | - | 6.21 | - |
| Total | 14.45 | 11.56 | 8.64 | 10.67 |
8
SAIDI for total interruptions
11
SAIDI classified
| Interruption Class | 2004 Powerco SAIDI | 2003 Powerco SAIDI | 2002 Powerco SAIDI | 2001 Powerco SAIDI |
|---|---|---|---|---|
| Class A - Transpower Planned | 12.86 | 3.46 | 8.82 | 7.51 |
| Class B - Distributor Planned | 21.93 | 46.99 | 38.02 | 23.59 |
| Class C - Distributor Unplanned | 304.35 | 234.35 | 91.92 | 60.84 |
| Class D - Transpower Unplanned | 31.04 | 10.37 | 20.59 | 3.75 |
| Class E - ECNZ Unplanned | - | 0.10 | - | - |
| Class F - Other Generator Unplanned | - | 0.18 | 0.22 | - |
| Class G - Other Line Owner Unplanned | - | 0.22 | - | - |
| Class H - Other Line Owner Planned | - | - | - | - |
| Class I - Other Owner (Not in A - H) | 0.24 | - | - | - |
| Total | 370.41 | 295.55 | 159.57 | 95.69 |
Note: 8 & 11. 2003 SAIDI, SAIFI and CAIDI are calculated using time weighted averages for all factors, i.e: using total Western plus 5/12 Eastern customer minutes, customer interruptions, and customers
9
SAIDI for the Following Financial Year
| Interruption Class | 2005 Powerco SAIDI | 2004 Powerco SAIDI | 2003 Powerco SAIDI | 2002 Powerco SAIDI |
|---|---|---|---|---|
| Class B - Distributor Planned | 20 | 29 | 26 | 25 |
| Class C - Distributor Unplanned | 130 | 101 | 73 | 75 |
10
SAIDI Targeted for the Following Financial Year and Subsequent 4 Financial Years
| Interruption Class | 2005 Powerco SAIDI | 2006-2009 Powerco SAIDI |
|---|---|---|
| Class B - Distributor Planned | 20 | 20 |
| Class C - Distributor Unplanned | 130 | 118 |
12
SAIFI for total interruptions
15
SAIFI classified
| Interruption Class | 2003 Powerco SAIFI | 2003 Powerco SAIFI | 2002 Powerco SAIFI | 2001 Powerco SAIFI |
|---|---|---|---|---|
| Class A - Transpower Planned | 0.029 | 0.033 | 0.038 | 0.030 |
| Class B - Distributor Planned | 0.114 | 0.249 | 0.192 | 0.150 |
| Class C - Distributor Unplanned | 3.258 | 2.930 | 2.045 | 1.420 |
| Class D - Transpower Unplanned | 0.385 | 0.257 | 0.275 | 0.230 |
| Class E - ECNZ Unplanned | - | - | - | - |
| Class F - Other Generator Unplanned | - | 0.002 | - | - |
| Class G - Other Line Owner Unplanned | - | 0.002 | 0.005 | - |
| Class H - Other Line Owner Planned | - | - | - | - |
| Class I - Other Owner (Not in A - H) | - | - | - | - |
| Total | 3.787 | 3.473 | 2.555 | 1.840 |
Note: 12 & 15. 2003 SAIDI, SAIFI and CAIDI are calculated using time weighted averages for all factors, i.e: using total Western plus 5/12 Eastern customer minutes, customer interruptions, and customers
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2005, No 13
Gazette.govt.nz —
NZ Gazette 2005, No 13
β¨ LLM interpretation of page content
π
Disclosure of Reliability Performance Measures Pursuant to Electricity Information Disclosure Requirements 2004
(continued from previous page)
π Trade, Customs & IndustryReliability Performance, Interruptions, Transpower, Distributor, ECNZ