✨ Electricity Performance Measures
Buller Electricity Limited
Line Business Performance Measures
10
Average SAIDI targets for 2004/2008 years
- Class B - Planned by Line Owners: 176
- Class C - Unplanned by Line Owners: 135
11
SAIDI for the total number of interruptions within each interruption class
| Class | 2003 | 2002 | 2001 | 2000 |
|---|---|---|---|---|
| Class A - Planned by Transpower | 0 | 0 | 0 | 0 |
| Class B - Planned by Buller Electricity | 222 | 136 | 173 | 218 |
| Class C - Unplanned by Buller Electricity | 144 | 154 | 141 | 147 |
| Class D - Unplanned by Transpower | 0 | 0 | 0 | 0.32 |
| Class E - Unplanned by Line Owner generation | 0 | 0 | 0 | 0 |
| Class F - Unplanned by other generator | 0 | 0 | 0 | 0 |
| Class G - Unplanned - by another line owner | 3.71 | 0 | 0 | 0.64 |
| Class H - Planned - by another Line Owner | 0 | 0 | 0 | 0 |
| Class I - Any Other Loss of Supply | — | 370 | 290 | 314 |
12
The SAIFI for the total number of interruptions
| Year | SAIFI |
|---|---|
| 2003 | 1.98 |
| 2002 | 1.84 |
| 2001 | 2.14 |
| 2000 | 3.11 |
13
SAIFI Targets for 2003/2004
- Class B - Planned by Line Owners: 0.55
- Class C - Unplanned by Line Owners: 1.33
14
Average SAIFI targets for 2004/2008 years
- Class B - Planned by Line Owners: 0.50
- Class C - Unplanned by Line Owners: 1.16
15
The SAIFI for the total number of interruptions within each interruption class
| Class | 2003 | 2002 | 2001 | 2000 |
|---|---|---|---|---|
| Class A - Planned by Transpower | 0.00 | 0.00 | 0.00 | 0.00 |
| Class B - Planned by Buller Electricity | 0.54 | 0.45 | 0.71 | 0.95 |
| Class C - Unplanned by Buller Electricity | 1.32 | 1.39 | 1.43 | 2.15 |
| Class D - Unplanned by Transpower | 0.00 | 0.00 | 0.00 | 0.01 |
| Class E - Unplanned by Line Owner generation | 0.00 | 0.00 | 0.00 | 0.00 |
| Class F - Unplanned by other generator | 0.00 | 0.00 | 0.00 | 0.00 |
| Class G - Unplanned - by another line owner | 0.12 | 0.00 | 0.00 | 0.00 |
| Class H - Planned - by another Line Owner | 0.00 | 0.00 | 0.00 | 0.00 |
| Class I - Any Other Loss of Supply | — | 1.98 | 1.84 | 2.14 |
16
The CAIDI for the total number of interruption
| Year | CAIDI |
|---|---|
| 2003 | 187 |
| 2002 | 158 |
| 2001 | 146 |
| 2000 | 118 |
17
CAIDI targets for 2003/2004
- Class B - Planned by Line Owners: 391
- Class C - Unplanned by Line Owners: 106
18
Average CAIDI Target for 2004/2008 years
- Class B - Planned by Line Owners: 355
- Class C - Unplanned by Line Owners: 117
19
The CAIDI for the total number of interruptions within each interruption class
| Class | 2003 | 2002 | 2001 | 2000 |
|---|---|---|---|---|
| Class A - Planned by Transpower | 0 | 0 | 0 | 0 |
| Class B - Planned by Buller Electricity | 411 | 305 | 242 | 229 |
| Class C - Unplanned by Buller Electricity | 109 | 110 | 99 | 68 |
| Class D - Unplanned by Transpower | 0 | 0 | 0 | 27 |
| Class E - Unplanned by Line Owner generation | 0 | 0 | 0 | 0 |
| Class F - Unplanned by other generator | 0 | 0 | 0 | 0 |
| Class G - Unplanned - by another line owner | 30 | 0 | 0 | 340 |
| Class H - Planned - by another Line Owner | 0 | 0 | 0 | 0 |
| Class I - Any Other Loss of Supply | — | 187 | 158 | 146 |
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2003, No 98
Gazette.govt.nz —
NZ Gazette 2003, No 98
✨ LLM interpretation of page content
🏗️
Buller Electricity Limited Performance Measures
(continued from previous page)
🏗️ Infrastructure & Public WorksPerformance Measures, Interruptions, Faults, SAIDI, SAIFI, CAIDI, Targets, Statistics, Electricity, Buller