Electricity System Statistics




NEW ZEALAND GAZETTE

No. 3

Dunedin
Area only

2002 2001 2000 1999

9 SAIDI target for next financial year (minutes)

Class B – planned by line owners | 15.0 | 10.0 | 10.0 | 3.0
Class C – unplanned by line owners | 75.0 | 80.0 | 80.0 | 34.5

10 Average SAIDI targets for next 5 years (minutes)

Class B – planned by line owners | 15.0 | 10.0 | 10.0 | 3.0
Class C – unplanned by line owners | 75.0 | 80.0 | 80.0 | 37.5

11 The SAIDI for the total number of interruptions within each interruption class (minutes)

Class A – planned by Transpower | - | - | - | -
Class B – planned by line owners | 13.8 | 16.7 | 18.9 | 2.7
Class C – unplanned by line owners | 61.5 | 62.4 | 175.7 | 48.2
Class D – unplanned by Transpower | 13.4 | 3.3 | 13.4 | -
Class E – unplanned by embedded generation | - | - | - | -
Class F – unplanned by generation on other networks | - | - | - | -
Class G – unplanned by other line owner | - | - | - | -
Class H – planned by another line owner | - | - | - | -
Class I – any other loss of supply | - | - | - | -

12 The SAIFI for the total number of interruptions

| 1.85 | 1.40 | 2.19 | 1.09 |

13 SAIFI target for next financial year

Class B – planned by line owners | 0.13 | 0.07 | 0.07 | 0.04
Class C – unplanned by line owners | 1.07 | 0.80 | 0.80 | 0.82

14 Average SAIFI targets for next 5 years

Class B – planned by line owners | 0.13 | 0.07 | 0.07 | 0.04
Class C – unplanned by line owners | 1.07 | 0.80 | 0.80 | 0.82

15 The SAIFI for the total number of interruptions within each interruption class

Class A – planned by Transpower | - | - | - | -
Class B – planned by line owners | 0.17 | 0.11 | 0.12 | 0.33
Class C – unplanned by line owners | 1.46 | 1.19 | 1.62 | 1.06
Class D – unplanned by Transpower | 0.23 | 0.11 | 0.45 | -
Class E – unplanned by embedded generation | - | - | - | -
Class F – unplanned by generation on other networks | - | - | - | -
Class G – unplanned by other line owner | - | - | - | -
Class H – planned by another line owner | - | - | - | -
Class I – any other loss of supply | - | - | - | -

16 The CAIDI for the total number of interruptions

| 47.90 | 58.6 | 94.9 | 46.7 |

17 CAIDI target for next financial year

Class B – planned by line owners | 120.0 | 150.0 | 150.0 | 72.0
Class C – unplanned by line owners | 70.0 | 100.0 | 100.0 | 42.2

18 Average CAIDI targets for next 5 years

Class B – planned by line owners | 120.0 | 150.0 | 150.0 | 72.0
Class C – unplanned by line owners | 70.0 | 100.0 | 100.0 | 45.9



Next Page →



Online Sources for this page:

VUW Te Waharoa PDF NZ Gazette 2003, No 3


Gazette.govt.nz PDF NZ Gazette 2003, No 3





✨ LLM interpretation of page content

🏗️ Electricity System Statistics for Dunedin Area (continued from previous page)

🏗️ Infrastructure & Public Works
Electricity, System Length, Transformer Capacity, Maximum Demand, Electricity Supplied, Consumers, Reliability Performance, Interruptions, Targets