3086 NEW ZEALAND GAZETTE No. 122
Dunedin Area Only
| 2000 | 1999 | 1998 | 1997 | |
|---|---|---|---|---|
| 8. The SAIDI for the total number of interruptions (minutes) | 208.1 | 50.9 | 37.2 | 58.3 |
| 9. SAIDI target for next financial year (minutes) | ||||
| Class B – planned by line owners | 10.0 | 3.0 | ||
| Class B – unplanned by line owners | 80.0 | 34.5 | ||
| 10. Average SAIDI targets for next 5 years (minutes) | ||||
| Class B – planned by line owners | 10.0 | 3.0 | ||
| Class C – unplanned by line owners | 80.0 | 37.5 | ||
| 11. The SAIDI for the total number of interruptions within each interruption class (minutes) | ||||
| Class A – planned by Transpower | - | - | - | - |
| Class B – planned by line owners | 18.9 | 2.7 | 4.7 | 2.1 |
| Class C – unplanned by line owners | 175.7 | 48.2 | 32.5 | 56.2 |
| Class D – unplanned by Transpower | 13.4 | - | - | - |
| Class E – unplanned by embedded generation | - | - | - | - |
| Class F – unplanned by generation on other networks | - | - | - | - |
| Class G – unplanned by other line owner | - | - | - | - |
| Class H – planned by another line owner | - | - | - | - |
| Class I – any other loss of supply | - | - | - | - |
| 12. The SAIFI for the total number of interruptions | 2.19 | 1.09 | 1.03 | 1.00 |
| 13. SAIFI target for next financial year | ||||
| Class B – planned by line owners | 0.07 | 0.04 | ||
| Class C – unplanned by line owners | 0.80 | 0.82 | ||
| 14. Average SAIFI targets for next 5 years | ||||
| Class B – planned by line owners | 0.07 | 0.04 | ||
| Class C – unplanned by line owners | 0.80 | 0.82 | ||
| 15. The SAIFI for the total number of interruptions within each interruption class | ||||
| Class A – planned by Transpower | - | - | - | - |
| Class B – planned by line owners | 0.12 | 0.33 | 0.06 | 0.05 |
| Class C – unplanned by line owners | 1.62 | 1.06 | 0.97 | 0.96 |
| Class D – unplanned by Transpower | 0.45 | - | - | - |
| Class E – unplanned by embedded generation | - | - | - | - |
| Class F – unplanned by generation on other networks | - | - | - | - |
| Class G – unplanned by other line owner | - | - | - | - |
| Class H – planned by another line owner | - | - | - | - |
| Class I – any other loss of supply | - | - | - | - |
| 16. The CAIDI for the total number of interruptions | 94.9 | 46.7 | 36.1 | 58.1 |
| 17. CAIDI target for next financial year | ||||
| Class B – planned by line owners | 150.0 | 72.0 | ||
| Class C – unplanned by line owners | 100.0 | 42.2 |
Next Page →
Online Sources for this page:
VUW Te Waharoa —
NZ Gazette 2000, No 122