✨ Electricity Performance Measures




13 SEPTEMBER NEW ZEALAND GAZETTE 2821

Regulation 22

Reliability Performance Measures
N.B. No information on targets is included as the business has been sold

  1. Class A

    • 31/3/99: 0
    • 31/3/98: 0
    • 31/3/97: 0
    • 31/3/96: 0

    Class B

    • 31/3/99: 31
    • 31/3/98: 133
    • 31/3/97: 153
    • 31/3/96: 144

    Class C

    • 31/3/99: 161
    • 31/3/98: 188
    • 31/3/97: 136
    • 31/3/96: 199

    Class D

    • 31/3/99: 0
    • 31/3/98: 0
    • 31/3/97: 0
    • 31/3/96: 1

    Class E

    • 31/3/99: 0
    • 31/3/98: 0
    • 31/3/97: 0
    • 31/3/96: 0

    Class F

    • 31/3/99: 0
    • 31/3/98: 0
    • 31/3/97: 0
    • 31/3/96: 0

    Class G

    • 31/3/99: 0
    • 31/3/98: 0
    • 31/3/97: 0
    • 31/3/96: 0

    TOTAL

    • 31/3/99: 192
    • 31/3/98: 321
    • 31/3/97: 289
    • 31/3/96: 344
  2. Percentage of Class C interruptions not restored within:
    a) 3 hours...

    • 31/3/99: 8.7%
      b) 24 hours...
    • 31/3/99: 0
  3. Total number of Faults per 100 Circuit Kilometres of Lines

    • 31/3/99: 8.90
    • 31/3/98: 10.54
    • 31/3/97: 7.73
    • 31/3/96: 11.62
  4. Total Number of Faults per 100 Circuit Kilometres of Underground Cable

    • 33kV...
      • 31/3/99: 0.00
      • 31/3/98: 0.00
      • 31/3/97: 0.00
      • 31/3/96: 0.00
    • 11kV...
      • 31/3/99: 11.40
      • 31/3/98: 8.29
      • 31/3/97: 8.71
      • 31/3/96: 9.13
    • 6.6kV...
      • 31/3/99: 0.00
      • 31/3/98: 0.00
      • 31/3/97: 0.00
      • 31/3/96: 0.00
        TOTAL...
      • 31/3/99: 10.90
      • 31/3/98: 7.92
      • 31/3/97: 8.45
      • 31/3/96: 10.28
  5. Total Number of Faults per 100 Circuit Kilometres of Overhead Lines

    • 33kV...
      • 31/3/99: 4.00
      • 31/3/98: 3.38
      • 31/3/97: 3.38
      • 31/3/96: 3.87
    • 11kV...
      • 31/3/99: 10.40
      • 31/3/98: 13.01
      • 31/3/97: 8.68
      • 31/3/96: 14.20
    • 6.6kV...
      • 31/3/99: 10.10
      • 31/3/98: 16.78
      • 31/3/97: 27.30
      • 31/3/96: 17.09
        TOTAL...
      • 31/3/99: 8.80
      • 31/3/98: 10.70
      • 31/3/97: 7.70
      • 31/3/96: 11.67
  6. The SAIDI for Total of Interruptions

    • 31/3/99: 202.80
    • 31/3/98: 211.50
    • 31/3/97: 216.44
    • 31/3/96: 431.73
  7. The SAIDI for Total of Interruptions within each Interruption Class
    Class A...

    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
      Class B...
    • 31/3/99: 21.42
    • 31/3/98: 73.12
    • 31/3/97: 113.23
    • 31/3/96: 76.72
      Class C...
    • 31/3/99: 181.38
    • 31/3/98: 138.34
    • 31/3/97: 103.22
    • 31/3/96: 339.16
      Class D...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 15.85
      Class E...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
      Class F...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
      Class G...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
  8. The SAIFI for Total of Interruptions

    • 31/3/99: 4.30
    • 31/3/98: 3.90
    • 31/3/97: 4.23
    • 31/3/96: 5.85
  9. The SAIFI for Total of Interruptions within each Interruption Class
    Class A...

    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
      Class B...
    • 31/3/99: 0.14
    • 31/3/98: 0.68
    • 31/3/97: 1.06
    • 31/3/96: 1.01
      Class C...
    • 31/3/99: 4.30
    • 31/3/98: 3.25
    • 31/3/97: 3.17
    • 31/3/96: 4.50
      Class D...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.34
      Class E...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
      Class F...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
      Class G...
    • 31/3/99: 0.00
    • 31/3/98: 0.00
    • 31/3/97: 0.00
    • 31/3/96: 0.00
  10. The CAIDI for Total of Interruptions

    • 31/3/99: 47.20
    • 31/3/98: 53.9
    • 31/3/97: 51.17
    • 31/3/96: 73.85


Next Page →

PDF embedding disabled (Crown copyright)

View this page online at:


VUW Te Waharoa PDF NZ Gazette 1999, No 117


NZLII PDF NZ Gazette 1999, No 117





✨ LLM interpretation of page content

🏭 Central Electric Limited Disclosure of Financial and Efficiency Performance Measures (continued from previous page)

🏭 Trade, Customs & Industry
Reliability Performance Measures, Class A, Class B, Class C, Class D, Class E, Class F, Class G, Faults, Interruptions, SAIDI, SAIFI, CAIDI, Circuit Kilometres, Underground Cable, Overhead Lines