β¨ Electricity Performance Measures
NEW ZEALAND GAZETTE
No. 84
ELECTRICITY ASHBURTON LIMITED LINE BUSINESS ACTIVITY PERFORMANCE MEASURES AND STATISTICS
DISCLOSURE OF FINANCIAL PERFORMANCE MEASURES AND EFFICIENCY MEASURES PURSUANT TO REGULATION 13 OF THE ELECTRICITY (INFORMATION DISCLOSURE) REGULATIONS 1994
1. Financial Performance Measures
(a) Accounting return on total assets: 2.0%
(b) Accounting return on equity: 0.8%
(c) Accounting rate of profit: 2.8%
2. Efficiency performance measures
(a) Direct line costs per kilometre: $1,247 / km
(b) Indirect line costs per electricity customer: $32 / customer
DISCLOSURE OF ENERGY EFFICIENCY PERFORMANCE MEASURES AND STATISTICS PURSUANT TO REGULATION 15 OF THE ELECTRICITY (INFORMATION DISCLOSURE) REGULATIONS 1994
1. Energy Delivery Efficiency Performance Measures
(a) Load Factor: 58.9%
(b) Loss Ratio: 6.8%
(c) Capacity Utilisation: 25.2%
2. Statistics
| Network Length | Overhead (b) | Underground (c) | Total (a) |
|---|---|---|---|
| 33kV | 248 km | 3 km | 251 km |
| 11kV | 1,723 km | 47 km | 1,770 km |
| 400 V | 120 km | 83 km | 203 km |
| TOTAL | 2,091 km | 133 km | 2,224 km |
(d) Distribution transformer capacity: 194,569 kVA
(e) Maximum demand: 49,047 kW
(f) Total electricity supplied from Network: 235,757,754 kWh
(g) Total electricity conveyed for other persons: 0 kWh
(h) Total customers: 12,915
DISCLOSURE OF RELIABILITY PERFORMANCE MEASURES PURSUANT TO REGULATION 16 OF THE ELECTRICITY (INFORMATION DISCLOSURE) REGULATIONS 1994
1. Total number of interruptions
| Number of Interruptions | |
|---|---|
| B - planned by line owner | 217 |
| C - unplanned by line owner | 225 |
| D - unplanned by Trans Power | 4 |
| A, E, F + G | 0 |
| TOTAL | 446 |
2. Total number of faults per 100 circuit kilometres of prescribed voltage electric line
| TOTAL | 11.13 |
| 33kV | 2.39 |
| 11kV | 12.37 |
3. Total number of faults per 100 circuit kilometres of underground prescribed voltage electric line
| TOTAL | 2.00 |
| 33kV | - |
| 11kV | 2.14 |
4. Total number of faults per 100 circuit kilometres of overhead prescribed voltage electric line
| TOTAL | 11.36 |
| 33kV | 2.42 |
| 11kV | 12.65 |
5. The SAIDI for the total of interruptions
249.11
6. The SAIDI within each interruption class
| Class | SAIDI |
|---|---|
| B - planned by line owner | 58.22 |
| C - unplanned by line owner | 126.65 |
| D - unplanned by Trans Power | 64.24 |
| A, E, F + G | 0.00 |
7. The SAIFI for the total number of interruptions
2.21
8. The SAIFI within each interruption class
| Class | SAIFI |
|---|---|
| B - planned by line owner | 0.29 |
| C - unplanned by line owner | 1.09 |
| D - unplanned by Trans Power | 0.83 |
| A, E, F + G | 0.00 |
9. The CAIDI for the total of all interruptions
112.72
10. The CAIDI within each interruption class
| Class | CAIDI |
|---|---|
| B - planned by line owner | 200.76 |
| C - unplanned by line owner | 116.19 |
| D - unplanned by Trans Power | 77.40 |
| A, E, F + G | 0.00 |
Next Page →
PDF embedding disabled (Crown copyright)
View this page online at:
VUW Te Waharoa —
NZ Gazette 1995, No 84
NZLII —
NZ Gazette 1995, No 84
β¨ LLM interpretation of page content
π
Electricity Ashburton Limited - Line Business Activity Performance Measures and Statistics
(continued from previous page)
π Trade, Customs & IndustryFinancial Performance, Efficiency Measures, Energy Delivery, Network Length, Distribution Transformer, Reliability Measures