LPG Approvals and Forestry Contracts




5744
THE NEW ZEALAND GAZETTE
No. 234

LPG Fuel System Approvals

Pursuant to regulation 90B of the Traffic Regulations 1976* (as inserted by the Traffic Regulations 1976, Amendment No. 7) and pursuant to the powers delegated to me by the Secretary for Transport, I, Robert Norman Abram, Chief Automotive Engineer, hereby approve the components listed in the Schedule hereto for inclusion in any LPG automotive fuel system installed and operated in accordance with the requirements of New Zealand Standard NZS 5422, Part 1, 1980 (and any standard made in amendment thereto or in substitution therefor) subject to the conditions (if any) set out in respect of any component in the said Schedule.

SCHEDULE
LPG FUEL CYLINDERS

MOT Reference Manufacturer Country of Origin Specification Material Inspection Authority Working Pressure Rating (MPa) Test Pressure (MPa)
AF LO3B 028 Crown Sheetmetal New Zealand AS 1210 Int 1 Stainless Steel Lloyds 2.55 3.3

CONDITIONS OF APPROVAL

  1. That they be permanently and clearly marked, on a suitably attached metal plate, with characters not less than 6 mm high if space permits but in any case not less than 3 mm high, displaying the following information:
    (a) The specification to which the cylinder was manufactured.
    (b) The manufacturer’s name or mark and the serial number of the cylinder.
    (c) The date of the original cylinder inspection and the identification mark of the inspection authority who made the inspection.
    (d) The date of any periodic cylinder test and the identification mark of the cylinder testing station who made each test.
    (e) The cylinder test pressure.
    (f) The nominal water capacity of the cylinder.
    (g) The tare weight of the cylinder.

  2. That they be clearly marked or labelled to indicate that the cylinder is suitable for use with LPG.

  3. That they be provided with valve threads and fittings which provide the following functions—
    (a) Filling connection incorporating a non return valve.
    (b) Service valve incorporating an excess flow valve.
    (c) Contents gauge.
    (d) Pressure—relief valve.
    (e) A fixed liquid level indicator or an automatic fill shut off device which prevents the cylinder being filled beyond 85 percent of the total cylinder capacity.
    Valves and fittings shall have a service pressure rating of at least that of the cylinder to which they are fitted and shall be dimensioned, threaded and marked in accordance with the requirements of section 2.3 of New Zealand Standard NZS 5422 “The use of LPG and CNG Fuels in Internal Combustion Engines—Part 1 LPG Fuel”.

  4. That they be tested prior to installation and at periods not exceeding 5 years in accordance with the requirements of Australian Standard AS 2337-1980 or in accordance with the periodic test requirements laid down in the specification to which the cylinder was manufactured.

Dated at Wellington this 6th day of December 1985.

R. N. ABRAM, Chief Automotive Engineer.

*S.R. 1976/227
(M.O.T. 14/1/17/16)

New Zealand Forest Service—Schedule of Contracts for Sale of Wood of $6,000 or More in Value

LOG SALE ON TRUCK (CLEARFELLING)

Conservancy Forest Purchaser Species Type Price per m³ $ Volume m³ Value $
Auckland Coromandel Forest Park Tasman Forestry Ltd. P. radiata sawlogs 51.54 31 756 1,636,704
P. elliottii/ taeda/ patula sawlogs 47.54 14 944 710,438
Tairua Tasman Forestry Ltd. P. radiata P. elliottii/ taeda sawlogs 49.04 45.04 139 908 17 292 6,861,088 778,832
Coromandel/ Tairua/ Marantaua Tasman Forestry Ltd. P. palustris P. radiata/ elliottii/ taeda/ nana sawlogs pulp 43.04 12.00 33 050 10 000 1,422,472 120,000
Tairua Pine Processors Ltd. P. radiata/ taeda/ elliottii/ palustris 2nd grade sawlogs 18.00) 21.50) 18–27 000 430,000

STANDING TREE (THINNINGS)

| Auckland | Purcora Forest Park | Braithwaite Timbers Ltd. | Thuja Plicata Cupressus Lawsoniana | sawlogs | 9.20 | 4100 | 37,720 |

STANDING TREE (CLEARFELLING)

| Wellington | Santoñ | T & J McIlwaine | P. radiata | pruned sawlogs unpruned sawlogs smallwood pulp | 62.00 42.00 14.00 6.00 | 322) 478) 34) 115) | 41,206 |

LOG SALE AT FOREST RIDE (THINNINGS)

| Southland | Herbert | Palmerston Timber Ltd. | P. radiata | prepared sawlogs | 42.55 | 5000 | 212,750 |

170
25



Next Page →

PDF embedding disabled (Crown copyright)

View this page online at:


VUW Te Waharoa PDF NZ Gazette 1985, No 234


NZLII PDF NZ Gazette 1985, No 234





✨ LLM interpretation of page content

🚂 LPG Fuel System Approvals (continued from previous page)

🚂 Transport & Communications
6 December 1985
LPG fuel cylinders, automotive fuel systems, approvals, regulations
  • Robert Norman Abram, Chief Automotive Engineer

🌾 Schedule of Contracts for Sale of Wood

🌾 Primary Industries & Resources
Forestry, log sales, contracts, wood sales, New Zealand Forest Service
  • Robert Norman Abram, Approved LPG components
  • T & J McIlwaine, Purchased standing trees