(1.) Where electricity is used for signalling, the pressure in any one circuit shall not exceed 25 volts.
(2.) Contact-makers shall be so constructed as to prevent the accidental closing of the circuit.
(3.) Adequate precautions shall be taken to prevent signal and telephone wires from touching cables and apparatus. -
Any of the requirements of this part of these regulations shall not apply in any case in which exemption is obtained from the Minister on the ground either of emergency or special circumstances, on such conditions as the Minister may prescribe.
ELECTRICITY ON SURFACE.
- The preceding provisions pertaining to electricity shall apply to apparatus used above ground, subject to the following amendments:
(1.) In Regulation 242 and Regulation 256 (3) the words “at the surface of the mine” shall be substituted in every case for the words “in the mine.”
(2.) Regulations 243, 244, 245 (d), 161, 248 (2), 253 (1), 257, 259, and 260 (1) shall not apply.
(3.) The following regulation shall be substituted for Regulation 248 (1) thereof:
“Where necessary to prevent danger or mechanical damage, apparatus shall be placed in a separate room, compartment, or box of fireproof construction. Inflammable or explosive material shall not be stored in any such room, compartment, or box.”
(4.) Regulation 250 (2) is amended by adding thereto the words: “Except that in the case of a portable lamp or other portable apparatus of small current capacity, connected to the system by means of a flexible cable complying with Regulation 255 (1), the cross-sectional area of the earthing-conductor in the flexible cable shall not be required to be greater than the cross-sectional area of either of the live conductors in the same flexible cable.”
(5.) The following regulation shall be substituted for Regulation 254 thereof:
“Unless so placed or otherwise safeguarded as to prevent danger, all cables other than flexible cables for portable apparatus and signal and telephone wires shall comply with the following requirements:
“(a.) They shall be covered with insulating-material (except that the outer conductor of a concentric system may be bare). The lead sheath of lead-sheathed cables and the iron or steel armouring of armoured cables shall be of not less thickness respectively than is recommended by the British Engineering Standards Association.
“(b.) They shall be efficiently protected from mechanical damage and supported at sufficiently frequent intervals and in such a manner as adequately to prevent danger and damage to the cables.
“(c.) Concentric cables, or two-core or multi-core cables protected by a metallic covering, or single-core cables protected by a metallic covering which shall contain all the conductors of the circuit, shall be used (i) where the pressure exceeds low pressure and (ii) where there may be risk of igniting coal-dust or other inflammable material: Provided that if the medium-pressure direct-current system is used, the single-core cables protected by metallic coverings may be used for any circuit.
“(d.) Cables unprotected by a metallic covering shall be properly secured to efficient insulators.
“(e.) The metallic covering of every cable shall be (i) electrically continuous throughout; (ii) earthed, if it is required by Regulation 250 (1) to be earthed by a connection to the earthing system of not less conductivity than the same length of the said metallic covering; (iii) efficiently protected against corrosion where necessary; (iv) of a conductivity at all parts and at all joints at least equal to 50 per cent. of the conductivity of the largest conductor enclosed by the said metallic covering; and (v) where there may be risk of igniting coaldust or other inflammable material, so constructed as to prevent as far as is practicable any fault or leakage of current from the live conductors from causing open sparking.
“(f.) Cables and conductors where jointed up to motors, transformers, switch-gear, and other apparatus shall be installed so that (i) they are mechanically protected by securely attaching the metallic covering (if any) to the apparatus, and (ii) the insulating material at each cable, and is efficiently sealed so as to prevent the diminution of its insulating properties. Where necessary to prevent abrasion there shall be properly constructed bushes.”
(6.) Regulation 255 (3) is amended to read: “At every point where flexible cables for portable apparatus are joined to main cables a switch capable of entirely cutting off the pressure from the flexible cables shall be provided.”
(7.) Regulation 256 (6) shall not apply.
(8.) The following regulation shall be substituted for Regulation 256 (8) thereof;
“The person authorized to work an electrically driven portable machine shall not leave the machine while it is working, and shall, before leaving the machine, ensure that the pressure is cut off from the flexible trailing cable which supplies such portable machine. Trailing cables shall not be dragged along by the machine when working.”
(9.) The last sentence of Regulation 256 (9) shall not apply.
(10.) In Regulation 260 (2) the words “used for signalling” shall be inserted after “contact-makers.”
PENALTY.
- The fine payable for a breach of any of the foregoing regulations shall, where no penalty is elsewhere provided, be for a first offence not exceeding £10, and for a second or subsequent offence not exceeding £20.
SCHEDULE.
FORM 1.
[Reg. 7.
The Coal-mines Act, 1925.
FIRST-CLASS MINE-MANAGER'S CERTIFICATE (BY EXAMINATION).
No.
Office of Board of Examiners,
Wellington, , 19
This is to certify that [State the name in full, address, and occupation of person examined] has produced a certificate from his previous employers that he has been actually engaged in underground workings in a mine for the necessary period, and has passed a satisfactory written and oral examination as a first-class mine-manager of a coal-mine, as required by the Coal-mines Act, 1925, and the regulations made thereunder.
A.B.,
Chairman of Board of Examiners.
Entered, Vol. , folio.
C.D., Secretary.
FORM 2.
[Reg. 7.
The Coal-mines Act, 1925.
SECOND-CLASS MINE-MANAGER'S CERTIFICATE (BY EXAMINATION).
No.
Office of Board of Examiners.
Wellington, , 19
This is to certify that [State the name in full, address, and occupation of person examined] has produced a certificate from his previous employers that he has been actually engaged in underground workings in a mine for the necessary period, and has passed a satisfactory written and oral examination as a second-class mine-manager of a coal-mine, as required by the Coal-mines Act, 1925, and the regulations made thereunder.
A.B.,
Chairman of Board of Examiners.
Entered, Vol. , folio.
C.D., Secretary.
FORM 3.
[Reg. 19.
The Coal-mines Act, 1925.
MINE-MANAGER'S CERTIFICATE OF COMPETENCY (BY EXCHANGE).
No.
Office of Board of Examiners,
Wellington, , 19
This is to certify that [State the name in full, address, and occupation of applicant] has produced a mine-manager's certificate granted in [Name of British possession or foreign country], and has satisfied the Board of Examiners that he is entitled to a first- [or second-] class mine-manager's certificate of competency under the provisions of the Coal-mines Act, 1925, and the regulations made thereunder, and this certificate is issued in compliance therewith.
A.B.,
Chairman of Board of Examiners.
Entered, Vol. , folio.
C.D., Secretary.
FORM 4.
[Reg. 12.
The Coal-mines Act, 1925.
MINE-SURVEYOR'S CERTIFICATE.
No.
Office of Board of Examiners,
Wellington, , 19
This is to certify that [State the name in full, address, and occupation of person] has complied with the requirements of the Coal-mines Act, 1925, and the regulations made thereunder, as regards the qualifications of a mine-surveyor, and has satisfied the Board of Examiners that he is competent to act as a mine-surveyor for the purpose of the above act.
A.B.,
Chairman of Board of Examiners.
Entered, Vol. , folio.
C.D., Secretary.
Next Page →
PDF embedding disabled (Crown copyright)
View this page online at:
VUW Te Waharoa —
NZ Gazette 1927, No 41
NZLII —
NZ Gazette 1927, No 41
✨ LLM interpretation of page content
🌾
Electricity Regulations in Mines
(continued from previous page)
🌾 Primary Industries & ResourcesElectricity, Safety, Mining, Regulations, Cables, Apparatus, Inspection, Earthing, High Pressure, Switch Gear, Cable Joints, Flexible Cables, Portable Apparatus, Electricians, Log-Book, Faults, Inflammable Gas, Coal-Dust, Haulage, Locomotives, Shot-Firing, Signalling, Contact-Makers, Signal Wires, Telephone Wires, Exemptions, Surface Apparatus, Fireproof Construction, Earthing-Conductor, Mechanical Damage, Corrosion, Sparking, Abrasion, Bushes, Trailing Cables, Penalties
🌾 First-Class Mine-Manager's Certificate by Examination
🌾 Primary Industries & ResourcesMining, Certification, Examination, First-Class Mine-Manager, Coal-Mines Act 1925
- A.B., Chairman of Board of Examiners
- C.D., Secretary
🌾 Second-Class Mine-Manager's Certificate by Examination
🌾 Primary Industries & ResourcesMining, Certification, Examination, Second-Class Mine-Manager, Coal-Mines Act 1925
- A.B., Chairman of Board of Examiners
- C.D., Secretary
🌾 Mine-Manager's Certificate of Competency by Exchange
🌾 Primary Industries & ResourcesMining, Certification, Competency, Exchange, Foreign Certificates, Coal-Mines Act 1925
- A.B., Chairman of Board of Examiners
- C.D., Secretary
🌾 Mine-Surveyor's Certificate
🌾 Primary Industries & ResourcesMining, Certification, Surveyor, Competency, Coal-Mines Act 1925
- A.B., Chairman of Board of Examiners
- C.D., Secretary